If narrower bushings are required for certain applications, these can be obtained simply by turning or parting off a standard bushing: lubrication holes may also be added later by drilling. In any case, burrs protruding into the sliding surface after machining must be carefully removed.
GLYCODUR® F and A bushings are supplied ready for installation. Any subsequent machining of the bore, i.e. the sliding surface, should only be undertaken in exceptional cases, as this will reduce the service life of the bushings. In some cases the bore can be calibrated using a mandrel when using GLYCODUR F bushings (see figure).
 |
| dK |
= |
diameter of calibration mandrel |
| B |
= |
bushing width |
| Minimum hardness: 50 HRC |
| Roughness: RZ ≈ 1μm (40 μin) |
|
Calibration mandrel |